14 usart manchester configuration register – Rainbow Electronics AT91CAP9S250A User Manual

Page 576

Advertising
background image

576

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

35.7.14

USART Manchester Configuration Register

Name:

US_MAN

Access Type:

Read/Write

• TX_PL: Transmitter Preamble Length

0: The Transmitter Preamble pattern generation is disabled

1 - 15: The Preamble Length is TX_PL x Bit Period

• TX_PP: Transmitter Preamble Pattern

• TX_MPOL: Transmitter Manchester Polarity

0: Logic Zero is coded as a zero-to-one transition, Logic One is coded as a one-to-zero transition.

1: Logic Zero is coded as a one-to-zero transition, Logic One is coded as a zero-to-one transition.

• RX_PL: Receiver Preamble Length

0: The receiver preamble pattern detection is disabled

1 - 15: The detected preamble length is RX_PL x Bit Period

• RX_PP: Receiver Preamble Pattern detected

• RX_MPOL: Receiver Manchester Polarity

0: Logic Zero is coded as a zero-to-one transition, Logic One is coded as a one-to-zero transition.

31

30

29

28

27

26

25

24

DRIFT

RX_MPOL

RX_PP

23

22

21

20

19

18

17

16

RX_PL

15

14

13

12

11

10

9

8

TX_MPOL

TX_PP

7

6

5

4

3

2

1

0

TX_PL

TX_PP

Preamble Pattern default polarity assumed (TX_MPOL field not set)

0

0

ALL_ONE

0

1

ALL_ZERO

1

0

ZERO_ONE

1

1

ONE_ZERO

RX_PP

Preamble Pattern default polarity assumed (RX_MPOL field not set)

0

0

ALL_ONE

0

1

ALL_ZERO

1

0

ZERO_ONE

1

1

ONE_ZERO

Advertising