Figure 38-8 – Rainbow Electronics AT91CAP9S250A User Manual

Page 658

Advertising
background image

658

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

Figure 38-8. WAVSEL= 00 with trigger

38.5.11.2

WAVSEL = 10

When WAVSEL = 10, the value of TC_CV is incremented from 0 to the value of RC, then auto-
matically reset on a RC Compare. Once the value of TC_CV has been reset, it is then
incremented and so on. See

Figure 38-9

.

It is important to note that TC_CV can be reset at any time by an external event or a software
trigger if both are programmed correctly. See

Figure 38-10

.

In addition, RC Compare can stop the counter clock (CPCSTOP = 1 in TC_CMR) and/or disable
the counter clock (CPCDIS = 1 in TC_CMR).

Figure 38-9. WAVSEL = 10 Without Trigger

Time

Counter Value

R

C

R

B

R

A

TIOB

TIOA

Counter cleared by compare match with 0xFFFF

0xFFFF

Waveform Examples

Counter cleared by trigger

Time

Counter Value

R

C

R

B

R

A

TIOB

TIOA

Counter cleared by compare match with RC

0xFFFF

Waveform Examples

Advertising