714

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

• SERR: Stuffing Error Interrupt Disable

0 = No effect.

1 = Disable Stuffing Error interrupt.

• AERR: Acknowledgment Error Interrupt Disable

0 = No effect.

1 = Disable Acknowledgment Error interrupt.

• FERR: Form Error Interrupt Disable

0 = No effect.

1 = Disable Form Error interrupt.

• BERR: Bit Error Interrupt Disable

0 = No effect.

1 = Disable Bit Error interrupt.