6 plla and pllb characteristics, 7 utmi pll characteristics – Rainbow Electronics AT91CAP9S250A User Manual

Page 964

Advertising
background image

964

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

Note:

These characteristics apply only when Main Oscillator is in Bypass Mode (i.e., when MOSCEN = 0 and OSCBYPASS = 1) in the
CKGR_MOR register. See PMC Clock Generator Main Oscillator Register in

Section 29. ”Power Management Controller

(PMC)” on page 354

.

47.6

PLLA and PLLB Characteristics

The PLLA and PLLB are identical and their characteristics are described in

Table 47-9

.

The following characteristics are applicable to the operating temperature range: T

A

= -40°C to 85°C and worst case of

power supply, unless otherwise specified.

Note:

1. Startup time depends on PLL RC filter. A calculation tool is provided by Atmel.

47.7

UTMI PLL Characteristics

The following characteristics are applicable to the operating temperature range: T

A

= -40°C to 85°C and worst case of

power supply, unless otherwise specified.

t

CLXIN

XIN Clock Low Half-period

0.4 x t

CPXIN

0.6 x t

CPXIN

C

IN

XIN Input Capacitance

(1)

5

pF

R

IN

XIN Pulldown Resistor

(1)

500

k

Table 47-9.

Phase Lock Loop A and B Characteristics

Symbol

Parameter

Conditions

Min

Typ

Max

Unit

F

IN

Input Frequency

1

32

MHz

F

OUT

Output Frequency

Field OUT of CKGR_PLL is 00

80

200

MHz

Field OUT of CKGR_PLL is 10

190

240

MHz

I

PLL

Current Consumption

active mode

3

mA

standby mode

1

µA

Table 47-10. Phase Lock Loop Characteristics

Symbol

Parameter

Conditions

Min

Typ

Max

Unit

F

IN

Input Frequency

4

12

32

MHz

F

OUT

Output Frequency

450

480

600

MHz

I

PLL

Current Consumption

active mode

5

8

mA

standby mode

TBD

µA

Table 47-8.

XIN Clock Electrical Characteristics in Bypass Mode

Symbol

Parameter

Conditions

Min

Max

Units

Advertising