PMC Clock Generator Main Clock Frequency Register

Register Name:

CKGR_MCFR

Access Type:

Read-only

• MAINF: Main Clock Frequency

Gives the number of Main Clock cycles within 16 Slow Clock periods.

• MAINRDY: Main Clock Ready

0 = MAINF value is not valid or the Main Oscillator is disabled.

1 = The Main Oscillator has been enabled previously and MAINF value is available.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

MAINRDY

15

14

13

12

11

10

9

8

MAINF

7

6

5

4

3

2

1

0