1 main oscillator connections, 2 main oscillator startup time, 3 main oscillator control – Rainbow Electronics AT91CAP9S250A User Manual

Page 350

Advertising
background image

350

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

Figure 28-2. Main Oscillator Block Diagram

28.3.1

Main Oscillator Connections

The Clock Generator integrates a Main Oscillator that is designed for a 8 to 16 MHz fundamental
crystal. The typical crystal connection is illustrated in

Figure 28-3

. For further details on the elec-

trical characteristics of the Main Oscillator, see the section “DC Characteristics” of the product
datasheet.

Figure 28-3. Typical Crystal Connection

28.3.2

Main Oscillator Startup Time

The startup time of the Main Oscillator is given in the DC Characteristics section of the product
datasheet. The startup time depends on the crystal frequency and decreases when the fre-
quency rises.

28.3.3

Main Oscillator Control

To minimize the power required to start up the system, the main oscillator is disabled after reset
and slow clock is selected.

The software enables or disables the main oscillator so as to reduce power consumption by
clearing the MOSCEN bit in the Main Oscillator Register (CKGR_MOR).

XIN

XOUT

MOSCEN

Main

Oscillator

Counter

OSCOUNT

MOSCS

MAINCK

Main Clock

Main Clock

Frequency

Counter

MAINF

MAINRDY

SLCK

Slow Clock

Main

Oscillator

1K

XIN

XOUT

GND

AT91 Microcontroller