4 transmit status register – Rainbow Electronics AT91CAP9S250A User Manual

Page 813

Advertising
background image

813

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

42.5.4

Transmit Status Register

Register Name:

EMAC_TSR

Access Type:

Read/Write

This register, when read, provides details of the status of a transmit. Once read, individual bits may be cleared by writing 1
to them. It is not possible to set a bit to 1 by writing to the register.

• UBR: Used Bit Read

Set when a transmit buffer descriptor is read with its used bit set. Cleared by writing a one to this bit.

• COL: Collision Occurred

Set by the assertion of collision. Cleared by writing a one to this bit.

• RLE: Retry Limit exceeded

Cleared by writing a one to this bit.

• TGO: Transmit Go

If high transmit is active.

• BEX: Buffers exhausted mid frame

If the buffers run out during transmission of a frame, then transmission stops, FCS shall be bad and tx_er asserted. Cleared
by writing a one to this bit.

• COMP: Transmit Complete

Set when a frame has been transmitted. Cleared by writing a one to this bit.

• UND: Transmit Underrun

Set when transmit DMA was not able to read data from memory, either because the bus was not granted in time, because
a not OK

hresp(bus error)

was returned or because a used bit was read midway through frame transmission. If this

occurs, the transmitter forces

bad

CRC. Cleared by writing a one to this bit.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

UND

COMP

BEX

TGO

RLE

COL

UBR