AT91CAP9S500A/AT91CAP9S250A

Figure 36-3. SSC Functional Block Diagram

36.6.1

Clock Management

The transmitter clock can be generated by:

• an external clock received on the TK I/O pad

• the receiver clock

• the internal clock divider

The receiver clock can be generated by:

• an external clock received on the RK I/O pad

• the transmitter clock

• the internal clock divider

Furthermore, the transmitter block can generate an external clock on the TK I/O pad, and the
receiver block can generate an external clock on the RK I/O pad.

This allows the SSC to support many Master and Slave Mode data transfers.