913

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

45.3.1

Data Timing

The two data timings using horizontal and vertical synchronization and EAV/SAV sequence syn-
chronization are shown in

Figure 45-3

and

Figure 45-4

.

In the VSYNC/HSYNC synchronization, the valid data is captured with the active edge of the
pixel clock (ISI_PCK), after SFD lines of vertical blanking and SLD pixel clock periods delay pro-
grammed in the control register.

The

ITU-RBT.656-4 defines the functional timing for an 8-bit wide interface.

There are two timing reference signals, one at the beginning of each video data block SAV
(0xFF000080) and one at the end of each video data block EAV(0xFF00009D). Only data sent
between EAV and SAV is captured. Horizontal blanking and vertical blanking are ignored. Use of
the SAV and EAV synchronization eliminates the ISI_VSYNC and ISI_HSYNC signals from the
interface, thereby reducing the pin count. In order to retrieve both frame and line synchronization
properly, at least one line of vertical blanking is mandatory.

Figure 45-3. HSYNC and VSYNC Synchronization

Figure 45-4. SAV and EAV Sequence Synchronization

ISI_VSYNC

ISI_HSYNC

ISI_PCK

Frame

1 line

Y

Cb

Y

Cr

Y

Cb

Y

Cr

Y

Cb

Y

Cr

DATA[7..0]

ISII_PCK

Cr

Y

Cb

Y

Cr

Y

Y

Cr

Y

Cb FF

00

DATA[7..0]

FF

00

00

80

Y

Cb

Y

00

9D

SAV

EAV