Rainbow Electronics AT91CAP9S250A User Manual

Page 833

Advertising
background image

833

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

42.5.26.7

Alignment Errors Register

Register Name:

EMAC_ALE

Access Type:

Read/Write

• ALE: Alignment Errors

An 8-bit register counting frames that are not an integral number of bytes long and have bad CRC when their length is trun-
cated to an integral number of bytes and are between 64 and 1518 bytes in length (1536 if bit 8 set in network configuration
register). This register is also incremented if a symbol error is detected and the frame is of valid length and does not have
an integral number of bytes.

42.5.26.8

Deferred Transmission Frames Register

Register Name:

EMAC_DTF

Access Type:

Read/Write

• DTF: Deferred Transmission Frames

A 16-bit register counting the number of frames experiencing deferral due to carrier sense being active on their first attempt
at transmission. Frames involved in any collision are not counted nor are frames that experienced a transmit underrun.

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

ALE

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

DTF

7

6

5

4

3

2

1

0

DTF