6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

42.5.12

PHY Maintenance Register

Register Name:

EMAC_MAN

Access Type:

Read/Write

• DATA

For a write operation this is written with the data to be written to the PHY.

After a read operation this contains the data read from the PHY.

• CODE:

Must be written to 10. Reads as written.

• REGA: Register Address

Specifies the register in the PHY to access.

• PHYA: PHY Address

• RW: Read/Write

10 is read; 01 is write. Any other value is an invalid PHY management frame

• SOF: Start of frame

Must be written 01 for a valid frame.

31

30

29

28

27

26

25

24

SOF

RW

PHYA

23

22

21

20

19

18

17

16

PHYA

REGA

CODE

15

14

13

12

11

10

9

8

DATA

7

6

5

4

3

2

1

0

DATA