6 mci command register – Rainbow Electronics AT91CAP9S250A User Manual

Page 780

Advertising
background image

780

6264A–CAP–21-May-07

AT91CAP9S500A/AT91CAP9S250A

41.10.6

MCI Command Register

Name: MCI_CMDR

Access Type: Write-only

This register is write-protected while CMDRDY is 0 in MCI_SR. If an Interrupt command is sent, this register is only write-
able by an interrupt response (field SPCMD). This means that the current command execution cannot be interrupted or
modified.

• CMDNB: Command Number

• RSPTYP: Response Type

• SPCMD: Special Command

• OPDCMD: Open Drain Command

0 = Push pull command

1 = Open drain command

• MAXLAT: Max Latency for Command to Response

0 = 5-cycle max latency

31

30

29

28

27

26

25

24

IOSPCMD

23

22

21

20

19

18

17

16

TRTYP

TRDIR

TRCMD

15

14

13

12

11

10

9

8

MAXLAT

OPDCMD

SPCMD

7

6

5

4

3

2

1

0

RSPTYP

CMDNB

RSP

Response Type

0

0

No response.

0

1

48-bit response.

1

0

136-bit response.

1

1

Reserved.

SPCMD

Command

0

0

0

Not a special CMD.

0

0

1

Initialization CMD:

74 clock cycles for initialization sequence.

0

1

0

Synchronized CMD:

Wait for the end of the current data block transfer before sending the
pending command.

0

1

1

Reserved.

1

0

0

Interrupt command:

Corresponds to the Interrupt Mode (CMD40).

1

0

1

Interrupt response:

Corresponds to the Interrupt Mode (CMD40).