8 read/write flowcharts – Rainbow Electronics AT91CAP9S250A User Manual
Page 493
493
6264A–CAP–21-May-07
AT91CAP9S500A/AT91CAP9S250A
34.7.8
Read/Write Flowcharts
The following flowcharts shown in
,
,
give
examples for read and write operations. A polling or interrupt method can be used to check the
status bits. The interrupt method requires that the interrupt enable register (TWI_IER) be config-
ured first.
Figure 34-14. TWI Write Operation with Single Data Byte without Internal Address
Set TWI clock
(CLDIV, CHDIV, CKDIV) in TWI_CWGR
(Needed only once)
Set the Control register:
- Master enable
TWI_CR = MSEN + SVDIS
Set the Master Mode register:
- Device slave address (DADR)
- Transfer direction bit
Write ==> bit MREAD = 0
Load Transmit register
TWI_THR = Data to send
Read Status register
TXRDY = 1?
Read Status register
TXCOMP = 1?
Transfer finished
Yes
Yes
BEGIN
No
No