34.7.8

Read/Write Flowcharts

The following flowcharts shown in

Figure 34-14

,

Figure 34-15 on page 494

,

Figure 34-16 on

page 495

,

Figure 34-17 on page 496

,

Figure 34-18 on page 497

and

Figure on page 497

give

examples for read and write operations. A polling or interrupt method can be used to check the
status bits. The interrupt method requires that the interrupt enable register (TWI_IER) be config-
ured first.

Figure 34-14. TWI Write Operation with Single Data Byte without Internal Address

Set TWI clock

(CLDIV, CHDIV, CKDIV) in TWI_CWGR

(Needed only once)

Set the Control register:

- Master enable

TWI_CR = MSEN + SVDIS

Set the Master Mode register:

- Device slave address (DADR)

- Transfer direction bit

Write ==> bit MREAD = 0

Load Transmit register

TWI_THR = Data to send

Read Status register

TXRDY = 1?

Read Status register

TXCOMP = 1?

Transfer finished

Yes

Yes

BEGIN

No

No

Advertising