Using the simunit – ABUS TV3220 User Manual

Page 108

Advertising
background image

ABUS VMS

ABUS Security-Center GmbH & Co. KG

System manual

Version 7.3

108

3.5.4 Using the SimUnit

The SimUnit is used for the simulation of external alarm
inputs and relay outputs (does not apply to ABUS VMS
Basic).

Using the SimUnit, complex application cases can be
simulated in advance and any problems can be analysed.

When the SimUnit is activated, 16 detectors are added to
the alarm detector list and 4 relays are added to the relay
list.

The current status of the interfaces can then be changed
or queried using the control panel.

Time-controlled alarm triggers can be generated using the
Random alarms... button. The time interval, hold time and
trigger behaviour can be changed here accordingly.

To switch on the SimUnit, open the system configuration and access the Digital I/O menu
point (point 2). Select the SimUnit menu point from the list on the left and check the On/Off
box. Save the settings and click on the Apply button.
























Alarm

detectors

1 to 16

Relays 1 to 4

Trigger
interval

Trigger time

of the

detectors

Trigger

behaviour of

the detectors

Advertising