ABUS TV3220 User Manual

Page 91

Advertising
background image

ABUS VMS

ABUS Security-Center GmbH & Co. KG

System manual

Version 7.3

91

2. An FTP server (Internet FTP server)

3. User authorisation for uploading the image data (log-in data)

4. A detector for event control (e.g. permanent alarm)

5. A timer (for time-controlled uploads)

6. A process used for uploading the image data

7. An activation for connecting all the components together


Activating the camera:

Open the system configuration and switch the view switch to the Camera view.

Open the TV33xx camera

branch from the list on the left.

Select the desired camera and activate it by checking the On/Off

box.

Save your settings.

FTP connection:

You can proceed with the upload process when storage space is available on the FTP server
and you know the log-in data. Otherwise, contact your system administrator or server provider.

Activating the detector:

For a successful FTP upload, a detector is required to start the process. An external event or
internal timer can be used as a trigger in this case. When using external events, activate a
detector under Detector/Key switch

TV33xx detector in the Digital I/O view (point 2) in the

system configuration.

When using a time-controlled FTP upload, the Permanent alarm detector must be activated

under Detector/Key switch

Virtual alarm detector

Detector 20.

Creating the timer:

If the upload process should be started with time control, then the system must be set up with
a timer.

More information on creating timers can be found under point 3.4.8 on side 96

(“Using

timers”).

Advertising
This manual is related to the following products: