14. I have added a Video-Out process, but no signal appears on the connected

monitor.

A process must always be connected to an activation

– creating the process alone is not sufficient.

Video-Out processes must be connected to the Permanent alarm virtual alarm detector. To do
this, activate detector 20 in the system configuration under Detector/Key switch

Virtual alarm

detector

(“Digital I/O” view).

Access the activations and create a new activation with the permanent alarm and Video-Out
process as described under point 3.4.9 (“Creating activations”).

15. Whilst viewing database images I have received a red image with the title: “You

are not authorised to view the image information”. What should I do now?

This message means that a database access restriction has been added for the user.

The permitted time for viewing database images is set up in the system configuration using the

permission levels (

“Security” view

Permissions).

The time (in hours) must be set in the Playback field and the permission level must be assigned to
a user. The function is deactivated when “0” is entered in the field.

Note:

The server settings always apply. The remote settings apply when a remote system is used for
dialling, not the local settings.

16. When calling a host, the software always shows a system error that the

connection was rejected or could not be established. What should I do now?

This may be because the network module (SocketUnit) is not switched on. Switch on the
module in the system configuration

(“Network” view

TCP/IP). More details on the

SocketUnit can be found under point 3.7.1 on page 119.