73
-
Save your settings.
-
If you wish to control the backup
using a timer, then this should
be created as detailed under
point 3.4.8 on page 96. The
Permanent alarm detector is
then used as the trigger. This is
switched on in the system
configuration under Digital I/O
Detector/Key
switch
Virtual detector
Detector 20.
-
Switch the view switch back to
the Actions view (point 3) and select Activations from the list on the left.
-
Press New, then create a new activation with the following data:
Detector: Permanent alarm or other event; Timer: Always or user-defined; Camera:
None; Process: Process created under point 7; Archive: None
For more details on creating activations, see point 3.4.9 on page 98.
Repeat the steps detailed above to create further backup processes. A separate backup
process must be created for each individual archive. However, these can all be started using
one detector.
To make an automatic backup in “BGV-Kassen” mode, the process must be dependent on
virtual alarm detector 1 (Alarm archive is filled up to 60%).
Note:
As image archives can be very large and the backup process may take some time, we
recommend starting the process at time where a low amount of movement is expected (for
example, at night).
1.
Select the “Actions” view
2.
Select Backup processes
3.
Make the settings
4.