3.4.4 Using the check call process

The check call process is used to check the connection of all hosts in the host list. For
example, a system failure can then be detected quickly and relevant measures can be taken
to solve the problem.

Two detectors in the virtual detector list are used for monitoring the connection. These are
Check Call Error (detector 19) and Check Call OK (detector 21).

One of these detectors is triggered with every connection attempt to the hosts. For example, if
the detectors are connected to the notification process, then any failure in reaching the host
can be detected in good time.

The check call process is set up in the system configuration (Check call process point in the
Actions view (point 3)).

You can select the permission level here and compare the time on the remote system with the
local station, when necessary.

However, please note that the selected permission level must exist on the host and that this is
also permitted to change the system time.

The check call process is always activated, meaning it does not need to be switched on.