Setting up the upload process:

The upload process loads the actual image data to the FTP server from the database. To

create the process, switch the view switch in the system configuration to the Actions

view

(point 3).

Select FTP Upload from the list on the left and create a new process using the New button.

Assign a unique name for the process. This makes it easier to find the process when
assigning the activation.

Set the time interval (in seconds) in which the image data should be uploaded to the FTP
server.

Select the desired image resolution.

Enter the access data (server address, user name and password).

Enter a file name for the uploaded image.

Placeholders are entered as standard for the file name. These prevent the uploaded images
from being overwritten. The following placeholders can be used:

n

Camera name

Y

Year

M

Month

D

Day

If the existing image should always be overwritten, then a file name without placeholders
should be used.

Save your settings.

Creating an activation:

In the current view, select the Activations point from the list on the left.

Create a new activation with the following data:

Detector: Permanent alarm or external detector; Timer: Always or user-defined; Camera: As
required; Process: Set FTP upload; Archives: None

You can find further information on creating activations under point 3.4.9.