6 analog1 setup menu – Lingenfelter L460240000 Lingenfelter NCC-002 Nitrous Control Center v1.5 User Manual

Page 100

Advertising
background image

Lingenfelter NCC-002 Nitrous Control Center Installation and Operating Instructions

99

The Valid Range is 0.00 to 5.00 volts in 0.01 volt increments.

Access from the Controller:
From the Main screen, press the “SETUP” button, press the “DOWN” arrow button repeatedly until the TPS
Setup Menu selection is highlighted, and then press the “ENTER” button. Press the down arrow until the
"Manual Set Max Volts" selection is highlighted and then press the "ENTER" button. Use the “LEFT” and
”RIGHT” arrow buttons adjust the setting. Press the “SAVE” button to accept the new setting or press the “ESC”
button to exit with no change.

Access from the Computer Program:
From the

Status screen

, press the "Setup" button. The "TPS WOT Voltage" setting is found in the "TPS Input

Setup" dialog box under the "TPS Input" Tab. Click the "UP" and "DOWN" arrow buttons or type in any numeric
value in the valid ranges shown above.

7.6

Analog1 Setup Menu

The Analog Clutch Options and settings are available in the Analog1 Setup Menu. The current input options for
Analog1 are OFF or Clutch Position Sensor input.

Analog1 Clutch Option

The Analog Clutch Option allows the NCC-002 to read the clutch position sensor on vehicles with a 0-5 volt
output clutch position sensor. The clutch, therefore, becomes an activation enabler. Many newer vehicles use a
clutch sensor as opposed to the traditional clutch switch. This feature accepts rising or falling input types.

Access from the Controller:
From the

Main screen

, press the “SETUP” button. Press the “DOWN” arrow button repeatedly until the Analog1

Setup Menu selection is highlighted and then press the “ENTER” button. Once in the Analog1 Setup menu,
press the "ENTER" button to select the Analog Clutch option. Press the “YES” or “NO” button to change the
current selection. If the “NO” button is pressed no change will be made.

Advertising