Lingenfelter L460240000 Lingenfelter NCC-002 Nitrous Control Center v1.5 User Manual

Page 131

Advertising
background image

Setup Menu

130

Volt" selection is highlighted and then press the "ENTER" button. Use the “LEFT” and ”RIGHT” arrow buttons
adjust the setting. Press the “SAVE” button to accept the new setting or press the “ESC” button to exit with no
change.

Access from the Computer Program:
From the

Status screen

, press the "Setup" button. The "Sensor Min Voltage" option is found in the "Nitrous

Sensor Setup" dialog box under the "Nitrous Sensor" Tab. Click the "UP" and "DOWN" arrow buttons or type in
any numeric value in the valid ranges shown above.

Nitrous Pressure Maximum Voltage

This setting should be set to the voltage the Nitrous Sensor outputs at the maximum nitrous pressure.

The Valid Range is 0.0 to 5.0 volts in .1 volt increments.

Access from the Controller:
From the Main screen, press the “SETUP” button, press the “DOWN” arrow button repeatedly until the Fuel Psi
Menu selection is highlighted, and then press the “ENTER” button. Press the down arrow until the "N2O Psi Max
Volt" selection is highlighted and then press the "ENTER" button. Use the “LEFT” and ”RIGHT” arrow buttons
adjust the setting. Press the “SAVE” button to accept the new setting or press the “ESC” button to exit with no
change.

Access from the Computer Program:
From the

Status screen

, press the "Setup" button. The "Sensor Max Voltage" option is found in the "Nitrous

Sensor Setup" dialog box under the "Nitrous Sensor" Tab. Click the "UP" and "DOWN" arrow buttons or type in
any numeric value in the valid ranges shown above.