10 pulse frequency, 11 resume start percentage – Lingenfelter L460240000 Lingenfelter NCC-002 Nitrous Control Center v1.5 User Manual

Page 81

Advertising
background image

Nitrous Menus: Nitrous1 (N2O-1) and Nitrous2 (N2O-2)

80

See

Appendix B: Nitrous & Fuel Operation

for more information.

6.10

Pulse Frequency

This setting determines the number of times per second that the solenoids pulse. A lower setting generally will
provide a more linear power delivery, as well as allow for lower starting percentages to be used. A higher pulse
frequency results in more solenoid pulses per second, which is displayed in the graph setup of the Nitrous
Control Center software by more data points. The correct setup will be different depending on the type of
solenoids and bottle pressure used. Testing is the only way to determine the best frequency for each application.
This setting applies to the respective nitrous and fuel solenoids of for each stage.

NOTE—When changing the pulse frequency the current Nitrous Setup will be time altered. Be sure to
check the Nitrous and Fuel Settings after a Frequency change!

Access from the Controller:
From the

Main screen

, select the stage by pressing either the "N2O-1" button or the "N2O-2" button. Press the

“DOWN” arrow button to highlight the Pulse Frequency menu selection and then press the “ENTER” button.
Using the “UP” and ”DOWN” buttons selected the desired Pulse Frequency setting. Press “ENTER” to select the
new setting or press “BACK” to exit with no change.

Access from the Computer Program:
From the

Status screen

, select the stage by pressing either the "Nitrous1" button or the "Nitrous2" button. The

"Pulse Frequency" setting is found in the "Stage Solenoid Pulse Freuency" dialog box under the "Options" Tab.
Click on one of the settings in the scroll-down menu to select the desired pulse frequency setting.

See

Appendix B: Nitrous & Fuel Operation

for more information.

6.11

Resume Start Percentage

This setting determines the percent at which the Nitrous resumes if the user has to lift the throttle after the
nitrous system is active. This setting is only valid if the Hold And Wait option is ON. This setting is used with the
Resume Percent Per Pulse setting to build a Resume Ramp. If the Resume Start Percent is greater than the
current Nitrous percent, the Resume Ramp is ignored.

Valid Range is 10% to 100% in 1% increments. A setting of 100% disables this feature (no ramp / instant ON).

Access from the Controller:
From the

Main screen

, select the stage by pressing either the "N2O-1" button or the "N2O-2" button. Press the

Advertising