Lingenfelter NCC-002 Nitrous Control Center Installation and Operating Instructions

73

6.3

Nitrous Graph Setup

Nitrous Setup


The Nitrous Percentage can be adjusted for each Pulse during the Progressive Ramp. This is done using a 2-D
Graph Editor. Please see basic editing Instructions below. The Fuel Percentage/Ramp can be adjusted
independently of the Nitrous (see

Fuel Graph Setup

).

Access from the Controller:
From the

Main screen

, select the stage by pressing either the “N2O-1” button or the "N2O-2 button. Press the

“DOWN” arrow button repeatedly until the "Nitrous Graph Setup" menu selection is highlighted and then press
the “ENTER” button. Use the “LEFT” and “RIGHT” arrow buttons to move through the Nitrous Progressive
Ramp. To Edit and/or change the Nitrous Progressive Ramp, move the cursor to the position to Edit and press
the “EDIT” button. The editing cursor will appear at the position selected. Using the “UP” and “DOWN” arrow
buttons adjust the new percentage setting. Press the “ENTER” button to accept the new setting. Use the “LEFT”
and “RIGHT” arrow buttons to move to the next set point. Each cursor position represents One pulse of the
Nitrous Solenoid. Press the “EDIT” button and adjust the Nitrous Percentage as outlined above. Press “ENTER”
to accept the new setting.

NOTE—When the two set points are more than one pulse apart the Progressive Ramp will be automatically
filled in between the set points.

Press the “MENU” button to Exit and/or Save the new setting(s). From the Menu select Exit and press “ENTER”.
You will then be prompted to Save the new settings or Exit without saving. After the Nitrous data is saved you
will be prompted to copy the Nitrous setup to the Fuel setup.

NOTE—There are several selections available when you press the “MENU” button. Please see below for an
explanation of each.

Edit:

This selection exits the graph editor.

Clear Edit Points:

This selection will clear any edit points that are set in the Graph Screen. This does NOT
change any percentage setting, only the cursor is removed.

View Old Data:

This selection will display the Progressive Ramp that is stored in memory.

Restore Old Data:

This selection will restore the Progressive Ramp settings if any editing has been done
and NOT saved.

Zoom In:

This selection will zoom the X-Axis in.

Zoom Out:

This selection will zoom the X-Axis out.

Access from the Computer Program:
From the

Status screen

, select the stage by pressing either the "Nitrous1" button or the "Nitrous2" button. The