Lingenfelter NCC-002 Nitrous Control Center Installation and Operating Instructions

93

button continuously until the "Timer Setup Menu" is selected, then press "ENTER". Press the "DOWN" button
continuously until the "Timer On RPM" setting is highlighted, then press "ENTER". Using the “LEFT” and
”RIGHT” arrow buttons, adjust the setting. Press the “SAVE” button to accept the new setting or press the “ESC”
button to exit with no change.

Access from the Computer Program:
From the

Status screen

, press the "Timer" button. The "Output RPM On" option is found in the "RPM Based

Setup" dialog box under the "Options" Tab. Click the "UP" and "DOWN" arrow buttons or type in any numeric
value in the valid ranges shown above.

Timer RPM Output Off

This setting controls the RPM at which the timer is deactivated if the timer is setup as a RPM window switch
controlled output. The RPM Off setting must be at least 500 RPM's higher than the RPM On setting.

The valid range is 2000-16000 in 100 RPM increments.

Access from the Controller:

From the Main screen press the “SETUP” button and then press the “ENTER” button. Press the "DOWN"
button continuously until the "Timer Setup Menu" is selected, then press "ENTER". Press the "DOWN" button
continuously until the "Timer Off RPM" setting is highlighted, then press "ENTER". Using the “LEFT” and
”RIGHT” arrow buttons, adjust the setting. Press the “SAVE” button to accept the new setting or press the “ESC”
button to exit with no change.

Access from the Computer Program:
From the

Status screen

, press the "Timer" button. The "Output RPM Off" option is found in the "RPM Based

Setup" dialog box under the "Options" Tab. Click the "UP" and "DOWN" arrow buttons or type in any numeric
value in the valid ranges shown above.