8 afr setup menu – Lingenfelter L460240000 Lingenfelter NCC-002 Nitrous Control Center v1.5 User Manual

Page 105

Advertising
background image

Setup Menu

104

"Analog2 Config" dialog box under the "Analog2" Tab. Check the box to enable the Data Log Erase Option or
un-check the box to disable the option.

7.8

AFR Setup Menu

The following options are found in the AFR setup menu, which can be accessed by the "SETUP" button on the
main screen of the controller or through the Air-Fuel Ratio tab in the setup menu of the computer software. The
Air-Fuel Ratio can be read into the NCC-002 and logged. The AFR signal must be a 0-5 volt linear signal.

This feature can also be used as a safety feature to disable nitrous. By enabling the AFR option, the O2
wideband controller can be used to detect a lean condition. The controller can then disable the nitrous
accordingly.

AFR Option

By enabling the AFR option, the 0-5 volt output from an O2 wideband controller can be used to disable the
nitrous system if a lean cylinder condition is detected.

Access from the Controller:
From the

Main screen

, press the “SETUP” button. Press the “DOWN” arrow button repeatedly until the AFR

Setup Menu selection is highlighted and then press the “ENTER” button. Press the "ENTER" button to select the
"AFR Option", then the “YES” or “NO” button to change the current selection. If the “NO” button is pressed no
change will be made.

Access from the Computer Program:
From the

Status screen

, press the "SETUP" button. The "AFR Nitrous Disable" option is found under the "Air

Fuel Ratio" Tab. Click "ON" to disable the AFR Nitrous feature or "OFF" to Enable the feature.

AFR Nitrous Oxide Disable

This setting determines the Air Fuel Ratio at which the nitrous system is disabled due to a lean condition. A
setting of 0.0 will disable this feature. This setting is used along with the AFR Delay and AFR Disable Percent
settings.

The Valid Range is 0.0 to 20.0 in .1 increments.

Access from the Controller:
From the

Main screen

, press the “SETUP” button. Press the “DOWN” arrow button repeatedly until the AFR

Advertising