Lingenfelter L460240000 Lingenfelter NCC-002 Nitrous Control Center v1.5 User Manual

Page 76

Advertising
background image

Lingenfelter NCC-002 Nitrous Control Center Installation and Operating Instructions

75

Access from the Controller:
From the

Main screen

, select the stage by pressing either the “N2O-1” button or the "N2O-2" button. Press the

“DOWN” arrow button repeatedly until the Fuel Graph Setup menu selection is highlighted and then press the
“ENTER” button. Use the “LEFT” and “RIGHT” arrow buttons to move through the Fuel Progressive Ramp. To
Edit and/or change the Fuel Progressive Ramp move the cursor to the position to Edit and press the “EDIT”
button. The editing cursor will appear at the position selected. Using the “UP” and “DOWN” arrow buttons adjust
the new percentage setting. The Fuel Percentage can NOT be set less than Nitrous Percentage - Fuel Trim
(See IMPORTANT note below) unless the

fuel trim option

is changed from the default value of 0%. Press the

“ENTER” button to accept the new setting. Use the “LEFT” and “RIGHT” arrow buttons to move to the next set
point. Each cursor position represents One pulse of the Fuel Solenoid. Press the “EDIT” button and adjust the
Fuel Percentage as outlined above. Press “ENTER” to accept the new setting.

NOTE—When the two set points are more than one pulse apart the Progressive Ramp will be automatically
filled in between the set points.

Press the “MENU” button to Exit and/or Save the new setting(s). From the Menu select Exit and press “ENTER”.
You will then be prompted to Save the new settings or Exit without saving.

NOTE—There are several selections available when you press the “MENU” button. Please see below for an
explanation of each.

Exit:

This selection exits the Graph Editor.

Clear Edit Points:

This selection will clear any Edit Points that are set in the Graph Screen. This
does NOT change any Percentage setting, only the Cursor is removed.

View Old Data:

This selection will display the Progressive Ramp that is stored in memory.

Restore Old Data:

This selection will restore the Progressive Ramp settings if any Editing has been
done and NOT Saved.

View Nitrous Data:

This selection will display the current Nitrous setup on the screen.

Copy Nitrous Data:

This selection will copy the current Nitrous setup to the Fuel setup.

Zoom In:

This selection will Zoom the X-Axis in.

Zoom Out:

This selection will Zoom the X-Axis out.

Access from the Computer Program:
From the

Status screen

, select the stage by pressing either the "Nitrous1" button or the "Nitrous2" button. The

Fuel Graph is displayed under the "Fuel Graph" Tab. To move a single point, click on it and drag with mouse up
or down. You can use the "UP" and "Down" arrow keys to move the data point as well. By pressing CTRL + UP/
DOWN keys, you can move the data point in fine precision. To set an Edit point, double click on a data point.
An "X" will appear to mark the Edit point. When you select another point with a single click all points between the
Edit point and the Highlight point will auto fill as you drag the point. The SHIFT+LEFT/RIGHT keys move the
Highlight between data points. Use the scroll wheel and the right button on the mouse to zoom in or out. Single
click off from a data point and drag the mouse to move around a zoomed in window. Hit "ESC" to deselect the
edit point. You can also single click directly on highlighted Edit point to cancel. Click CTRL-Z to undo. Right-

Advertising