Format is shown in, Figure 24-23 – Freescale Semiconductor MCF5480 User Manual

Page 749

Advertising
background image

Programming Model

MCF548x Reference Manual, Rev. 3

Freescale Semiconductor

24-29

The base address for context save space is used to save variables and values being used by the MDE and

ADS. For each task, an area needs to be set aside for all relevant data to be saved until the task is called

again.

Figure 24-23. Task Descriptor Table Format

31

30

29

28

27

26

25

24

23

22

21

20

19

18

17

16

15

14

13

12

11

10

9

8

7

6

5

4

3

2

1

0

Ta

sk 0

Task Descriptor Start Pointer

Task Descriptor End Pointer

Variable Table Pointer

Function Descriptor Base Address

— PI S —

I

SP CW RL

Descriptor Address

MDE

Status

EU3

Status

Modified Variable Table Pointer

Base Address for Context Save Space

Literal

Base 0

Reserved

Literal Base 1

Reserved

...................

.

Ta

sk

n

Task Descriptor Start Pointer

Task Descriptor End Pointer

Variable Table Pointer

Function Descriptor Base Address

— PI S —

I

SP CW RL

Descriptor Address

MDE

Status

EU3

Status

Modified Variable Table Pointer

Base Address for Context Save Space

Literal Base 0

Reserved

Literal Base 1

Reserved

Note: For each task, the start pointer, end pointer, and variable table pointer are 32-bit values. For the task control bits, bits 31
through 8 are for the Function Descriptor Base Address, and bits 7 through 0 are control bits.

Table 24-20. Behavior of Task Table Control Bits

Bit

Name

Function

7

Reserved

6

PI

Precise Increment
0 Increments are allowed at any time the ADS can do it
1 Only increment at the end of an iteration

5

S

Save all internal registers
0 Save only those internal registers currently used when doing a context save
1 Save all internal registers when doing a context save

4

Reserved