7 clock synchronization and arbitration, 7 clock synchronization and arbitration -12 – Freescale Semiconductor ColdFire MCF52210 User Manual

Page 432

Advertising
background image

I

2

C Interface

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

25-12

Freescale Semiconductor

25.3.7

Clock Synchronization and Arbitration

I

2

C is a true multi-master bus that allows more than one master connected to it. If two or more master

devices simultaneously request control of the bus, a clock synchronization procedure determines the bus
clock. Because wire-AND logic is performed on the SCL line, a high-to-low transition on the SCL line
affects all the devices connected on the bus. The devices start counting their low period and after a device’s
clock has gone low, it holds the SCL line low until the clock high state is reached. However, change of low
to high in this device’s clock may not change the state of the SCL line if another device clock remains
within its low period. Therefore, synchronized clock SCL is held low by the device with the longest low
period.

Devices with shorter low periods enter a high wait state during this time (see

Figure 25-12

). When all

devices concerned have counted off their low period, the synchronized clock (SCL) line is released and
pulled high. At this point, the device clocks and the SCL line are synchronized, and the devices start
counting their high periods. The first device to complete its high period pulls the SCL line low again.

Figure 25-12. Clock Synchronization

A data arbitration procedure determines the relative priority of the contending masters. A bus master loses
arbitration if it transmits logic 1 while another master transmits logic 0. The losing masters immediately
switch over to slave receive mode and stop driving SDA output (see

Figure 25-13

). In this case, transition

from master to slave mode does not generate a STOP condition. Meanwhile, hardware sets I2SR[IAL] to
indicate loss of arbitration.

Figure 25-13. Arbitration Procedure

Internal Counter Reset

Wait

Start counting high period

SCL1

SCL2

SCL

Master 2 Loses Arbitration,
and becomes slave-receiver

SCL

SDA by
Master1

SDA by
Master2

SDA

Advertising