Analog-to-Digital Converter (ADC)

MCF52211 ColdFire® Integrated Microcontroller Reference Manual, Rev. 2

Freescale Semiconductor

26-23

Optional interrupts can be generated at the end of a scan sequence. Interrupts are available simply to
indicate the scan ended, that a sample was out of range, or at several different zero crossing conditions.
Out-of-range is determined by the high and low limit registers.

To understand the operation of the ADC, it is important to understand the features and limitations of each
of the functional parts.

26.5.1

Input MUX Function

The input MUX function is shown in

Figure 26-20

. The channel select and single ended vs. differential

switches are indirectly controlled based on settings within the LIST1, LIST2, and SDIS registers, and the
CHNCFG field of the CTRL1 register.

1. MUXing for Sequential mode, single-ended conversions—During each conversion cycle (sample),

any one input of the two muxes can be directed to any ADRSLTn register.

2. MUXing for sequential mode, differential conversions—During any conversion cycle (sample),

either member of a differential pair may be referenced as a SAMPLE, resulting in a differential
measurement on that pair being stored in the corresponding ADRSLTn register.

3. MUXing for parallel mode, single-ended conversions—During any conversion cycle (sample), any

of AN0-AN3 can be directed to ADRSLT0-3 and any of AN4-AN7 can be directed to ADRSLT4-7.

4. MUXing for parallel mode, differential conversions—During any conversion cycle (sample),

either member of differential pair AN0/1 or either member of differential pair AN2/3 can be
referenced as a SAMPLE, resulting in a differential measurement of that pair being stored in one
of the ADRSLT0-3 registers. Likewise, either member of differential pair AN4/5 or either member
of differential pair AN6/7 can be referenced as a SAMPLE, resulting in a differential measurement
of that pair being stored in one of the ADRSLT4-7 registers.

Details of switch operation is shown in

Table 26-20

. Internally, all measurements are performed

differentially. During single ended measurements, V

REFL

is used as the negative (-) input voltage, while

the selected analog input is used as the positive (

+

) input.

Table 26-20. Analog MUX Controls for Each Conversion Mode

Conversion Mode

Channel Select Switches

Single Ended Differential Switches

Sequential, Single Ended

The two 1-of-4 select muxes can be

set for the appropriate input line.

The lower switch selects V

REFL

for the

V- input of the A/D. The upper switch is

always closed so that any of the four

inputs can get to the V+ A/D input.

Sequential, Differential

The channel select switches are

turned on in pairs, providing a dual

1-of-2 select function, such that either
of the two differential channels can be

routed to the A/D input.

The upper switch is open and the

bottom switch selects the differential

channel for the V- input of the A/D.