Fault Fault Name

Description and Recommended Corrective Action

Code In Panel

27 CONFIG FILE

Internal configuration file has an error. Contact your local factory

representative.

• Cycle power

• Check Group 9902 / Drive Size Type

28 SERIAL 1 ERR

Fieldbus communication has timed out. Check for and correct:

• Fault setup (2409

COMM FAULT FUNC

and 2410

COMM FAULT TIME

).

• Communication settings (Group 31 or 32 as appropriate).

• Poor connections and/or noise on line.

29 EFB CON FILE

Error in reading the configuration file for the fieldbus adapter.

30 FORCE TRIP

Fault trip forced by the fieldbus. See the fieldbus User’s Manual.

31 EFB 1

Fault code reserved for the EFB protocol application.

32 EFB 2

The meaning is protocol dependent.

33 EFB 3
34 MOTOR PHASE

Fault in the motor circuit. One of the motor phases is lost.

Check for and correct:

• Motor fault

• Motor wiring, connections

• Motor cable fault

• Internal fault

35 OUTP WIRING

Error in power wiring suspected. Check for and correct:

• Input power wired to drive output

• Ground faults

101 SERF CORRUPT

Error internal to the drive. Contact your local factory

102 SERF IITFILE

representative and report the error number.

103 SERF MACRO
104 SERF EFBPROT
105 SERF BPFILE
201 DSP T1 OVERLOAD

Error internal to the drive. Contact your local factory

202 DSP T2 OVERLOAD

representative and report the error number.

203 DSP T3 OVERLOAD
204 DSP STACK ERROR
205 DSP REV ERROR
206 OMIO ID ERROR

Faults that indicate conflicts in the parameter settings are listed below.

1000 PAR HZRPM

Parameter values are inconsistent. Check for any of the following:

• 2001

MINIMUM SPEED

> 2002

MAXIMUM SPEED

.

• 2007

MINIMUM FREQ

> 2008

MAXIMUM FREQ

.

• 2001

MINIMUM SPEED

/ 9908

MOTOR NOM SPEED

> 128 (or < -128).

• 2002

MAXIMUM SPEED

/ 9908

MOTOR NOM SPEED

> 128 (or < -128).

• 2007

MINIMUM FREQ

/ 9907

MOTOR NOM FREQ

> 128 (or < -128).

• 2008

MAXIMUM FREQ

/ 9907

MOTOR NOM FREQ

> 128 (or < -128).

1001 PAR PFCREFNG

Parameter values are inconsistent. Check for the following:

• 2007

MINIMUM FREQ

is negative.

1003 PAR AI SCALE

Parameter values are inconsistent. Check for any of the following:

• 1503

TRANSDUCER

MIN

> 1502

TRANSDUCER

MAX

.

1004 PAR AO SCALE

Parameter values are inconsistent. Check for any of the following:

• 1904

AO

1

MIN

> 1905

AO

1

MAX

.

• 1909

AO

2

MIN

> 1910

AO

2

MAX

.