Maintenance – Xylem IM167 R8 Aquavar CPC (Centrifugal Pump Control) User Manual

Page 123

Advertising
background image

123

Frame Size R1…R4
To replace the fan:

1. Remove power from drive
2. Remove drive cover
3. For Frame Size:

• R1, R2: Press together the retaining clips on the fan cover sides

and lift.

• R3, R4: Press in on the lever located on the left side of the fan

mount and rotate the fan up and out.

4. Disconnect the fan cable.
5. Install the fan in reverse order
6. Restore power

Frame Size R5 and R6
To replace the fan:

1. Remove power from drive
2. Remove the screws attaching the fan
3. Disconnect the fan cable.
4. Install the fan in reverse order
5. Restore power

Internal Enclosure Fan Replacement

IP 54 / UL Type 12 enclosures have an additional internal fan
to circulate air inside the enclosure.

Frame Size R1 to R4
To replace the internal enclosure fan in frame sizes R1 to R4:

1. Remove power from drive
2. Remove the front cover
3. The housing that holds the fan in place has barbed retaining

clips at each corner. Press all four clips toward the center to
release the barbs.

4. When the clips/barbs are free, pull the housing up to remove

from the drive.

5. Disconnect the fan cable
6. Install the fan in reverse order

• The fan air flow is up (refer to arrow on fan)
• The fan wire harness is toward the front
• The notched housing barb is located in the right-rear corner
• The fan cable connects just forward of the fan at the top of

the drive

MAINTENANCE

(Frame Sizes R1-R6)

Advertising