Connecting Power and Control Cables

Additional considerations that apply with the enclosure extension:

• The power cable connection diagram that applies for the AQUAVAR is:

• Temporarily remove the upper high voltage shield (clear plastic) to gain access to the

power connections in the extension module.

• To avoid metal shavings inside the cabinet, temporarily remove the gland/conduit plate

at the top of the extension module. Then drill holes and mount conduit or cable fittings as
needed.

• Route all power and control wiring through the top of the extension module.

Extension Module

AQUAVAR

Drive Module

Control

Panel

Switch-fuse

Disconnect

3 ~

Motor

Supply

Control

Wiring

V2

U2

W2

V1

U1

3

3

3

L1 L2 L3 PE

U1

V1

W1

PE

PE

OMIO

W1

INSTALLATION

(Frames R7-R8)