148

3.25

0.875” HEX

Snubber

added

1/4 MNPT

LABEL

Packard 3-pin

Metri-Pack

Series 150

2

3

1

Output

White

+Supply

Brown

No

Connection

3/16” Dia

sphere of

silicon

grease at

base of

terminals

CentriPro

www.centripro.com

PART#: 9K515
PRESSURE: 0-300PSI
INPUT: 10-28VDC

MADE IN USA

OUTPUT: 4-20mA

SERIAL #: AXXXXXX

YYMMDD

C

US

LISTED

79BN

UL

0300SB

PRESSURE TRANSDUCER

300 PSI 4-20 mA

P/N 9K515

(To order sensor with 200 inch (16 ft.) cable, use P/N 9K391)

SPECIFICATIONS

Parameter

Value

Pressure Range

300 PSI

Output (0 - 100%)

4-20 mA

Supply Voltage

10-28 VDC

Burst Pressure Minimum

5x rated

Pressure Overload Maximum

2x rated

Supply Current Maximum

<22mA

Pressure Cycles Minimum

100 million

Accuracy (combined lin/hyst/rep)

< 0.5% BFSL

Zero Offset Maximum

< 1% of FS / ºC

Span Tolerance Maximum

< 2% of FS / ºC

Parameter

Value

Operating Temp. Range

-40 to 85°C

Compensation Temp. Range

0 to 55°C

Zero Thermal Error Maximum

< .035% of FS

Span Thermal Error Maximum

< .035% of FS

Pressure Port Material

17-4 PH

Housing Material

304 stainless steel

Isolation Voltage Minimum

500VDC

Seal Material

N/A

Listings

UL cUL 508