3 calculating the minimum cycle time, Calculating the minimum cycle time, Control technology | ethercat communication manual – Lenze EtherCAT control technology User Manual

Page 128

Advertising
background image

Control technology | EtherCAT communication manual

Defining the minimum cycle time of the PLC project

Calculating the minimum cycle time

128

L

DMS 3.1 EN 01/2011 TD17

10.3

Calculating the minimum cycle time

The minimum cycle time T

min

for a system results from the sum of the times detected

before, multiplied by the safety factor:
T

min

> Safety factor * ( T

Task utilisation

+ T

Correction

)

Example

Note!

The safety factor 1.5 is included in the calculation.

Configuration: System with Intel Celeron 1 GHz processor and six motion axes
Detected access time

Result

Calculated correction value

T

Correction

160 μs (= 130 μs + 6 * 5 μs

Value read from task configuration:

T

Task utilisation

500 μs

Actual required computing time

660 μs

Minimum cycle time including the safety factor 1.5

T

min

990 μs

Actual cycle time

1000 μs