Control technology | EtherCAT communication manual

Parameter reference

Interface parameters of the MC-ETC communication card in slot 2

C1581/4

C1581/5

C1581/6

Parameter | Name:

C1581/4 | ECAT Slaves in requested Mode

Data type: UNSIGNED_8

Index: 22994.4

d

=

0x59D2.0x04

h

• Value "0": One or more slaves are not in the state requested by the master.

• Value "1": All slaves are in the state requested by the master.
Display range

(min. value | unit | max. value)

0

1

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1581/5 | ECAT Master State Summary

Data type: BITFIELD_32

Index: 22994.5

d

=

0x59D2.0x05

h

Display of additional information about the current master state

The bits are set to the value 1 when the respective states are reached.
Value is bit-coded:

Bit 0 Master ok
Bit 1 Reserved 1
Bit 2 Reserved 2
Bit 3 Reserved 3
Bit 4 Init
Bit 5 Pre-Operational
Bit 6 Safe Operational
Bit 7 Operational
Bit 8 Slaves in Requested State
Bit 9 Master in Requested State

Bit 10 Bus Scan Match
Bit 11 Reserved 4
Bit 12 DC: Activated
Bit 13 DC: Synchronised
Bit 14 DC: Busy
Bit 15 Reserved 5
Bit 16 Link Up
Bit 17 Reserved 6

... ...

Bit 31 Reserved 20

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1581/6 | ECAT BusScan

Data type: UNSIGNED_8

Index: 22994.6

d

=

0x59D2.0x06

h

Activation of the bus scan

The bus scan updates all EtherCAT codes.
Selection list

(Lenze setting printed in bold)

0 No Operation
1 Scan Bus

;

Read access ; Write access … CINH … PLC STOP ; No transfer