6 error scenarios, Error scenarios, Control technology | ethercat communication manual – Lenze EtherCAT control technology User Manual

Page 145: Diagnostics error scenarios

Advertising
background image

DMS 3.1 EN 01/2011 TD17

L

145

Control technology | EtherCAT communication manual

Diagnostics

Error scenarios

11.6

Error scenarios

In the following sections, the causes and remedies for the most frequent user errors are

described.
The state diagram and the table on the next page serve to localise an error.

NO

PLC:

Original

EtherCAT:

Unknown

PLC:

Original

EtherCAT:

Init

PLC:

Original

EtherCAT: Pre-Operational

YES

NO

Read ECAT_MASTER_1.XML

Stop PLC

Load PLC

Executable boot project

available?

ECAT_MASTER_1.XML

OK?

Switch on industrial PC and field devices

PLC:

Original

EtherCAT: Pre-Operational

PLC:

Stop

EtherCAT: Pre-Operational

Start PLC

PLC:

Running

EtherCAT: Safe-Operational

PLC:

Running

EtherCAT:

Operational

ECAT_MASTER_1.XML

available?

YES

NO

YES

Load PLC

PLC:

Original

EtherCAT:

Unknown

PLC:

Stop

EtherCAT:

Unknown

Reset

(Original)

Call

<SMC_ResetAxisGroup>

POU

from PLC application

PLC:

Stop

EtherCAT: Pre-Operational

PLC:

Running

EtherCAT: Safe-Operational

Start PLC

Reset

(Original)

System is running

Load correct

ECAT_MASTER_1.XML

onto IPC

Reset

(Original)

Advertising