Error counters of the EtherCAT slaves

11.5

Error counters of the EtherCAT slaves

The EtherCAT slaves have numerical error counters for detecting and analysing error

states. All error counters have a limited counting range of 0 ... 255. After the maximum

value of 255 is reached, no "wrap-around" takes place. If the PLC application is to make a

sensible evaluation of the error counters, these must be deleted by the application after

the evaluation via a write access.

11.5.1

Error types: "Errors" and "Forwarded Errors"

The EtherCAT differ betweeen errors detected in the slave for the first time (red error) and

forwarded errors, i.e. errors that have already been detected in a previous slave (green

error).
When the corresponding error counters are evaluated, an error in the EtherCAT network

can be clearly assigned in a bus segment or a slave.

The different error counters are assigned to the following IPC parameters:

Error counters

MC-ETC in slot 1

MC-ETC in slot 2

Port 1

Port 2

Port 1

Port 2

Errors detected for the first time

(red error)

C1096/25

C1096/26

C1096/25

C1096/26

Forwarded errors

(green error)

C1096/29

C1096/30

C1096/29

C1096/30