Parameter reference

Interface parameters of the MC-ETC communication card in slot 2

C1596/11

C1596/12

C1596/13

Parameter | Name:

C1596/11 | ECAT Port State

Data type: BITFIELD_16

Index: 22979.11

d

=

0x59C3.0x0B

h

Display of the port states/connections (ports 0 ... 3) of a slave.

The states are bit-coded (WORD).
Value is bit-coded:

Bit 0 Port 0

1 (TRUE) = slave

connected (logical result

of bits 0 ... 11)

Bit 1 Port 1
Bit 2 Port 2
Bit 3 Port 3
Bit 4 Port 0

1 (TRUE) = link known

Bit 5 Port 1
Bit 6 Port 2
Bit 7 Port 3
Bit 8 Port 0

1 (TRUE) = loop closed

Bit 9 Port 1

Bit 10 Port 2
Bit 11 Port 3
Bit 12 Port 0

1 (TRUE) = signal received

Bit 13 Port 1
Bit 14 Port 2
Bit 15 Port 3

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596/12 | ECAT DC Support

Data type: UNSIGNED_8

Index: 22979.12

d

=

0x59C3.0x0C

h

Support of distributed clocks by the slave:

• Value "0": Distributed clocks are not supported.

• Value "1": Support of distributed clocks.
Display range

(min. value | unit | max. value)

0

1

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1596/13 | ECAT: DC Support 64-Bit

Data type: UNSIGNED_8

Index: 22979.13

d

=

0x59C3.0x0D

h

Support of distributed clocks (64 bits) by the slave:

• Value "0": Distributed clocks (64 bits) are not supported.

• Value "1": Support of distributed clocks (64 bits).
Display range

(min. value | unit | max. value)

0

1

;

Read access … Write access … CINH … PLC STOP … No transfer