Control technology | ethercat communication manual – Lenze EtherCAT control technology User Manual

Page 167

Advertising
background image

DMS 3.1 EN 01/2011 TD17

L

167

Control technology | EtherCAT communication manual

Parameter reference

Interface parameters of the MC-ETC communication card in slot 1

12.2

Interface parameters of the MC-ETC communication card in slot 1

The parameters are listed in numerically ascending order.

C1074

C1080/1

C1080/2

C1080/3

C1080/4

Parameter | Name:

C1074 | ECAT MAC address

Data type: VISIBLE_STRING

Index: 23501

d

= 5BCD

h

MAC address of the interface

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1080/1 | ECAT Master Configuration Date

Data type: DATE

Index: 23495.1

d

=

0x5BC7.0x01

h

Date of the master configuration file in the file system of the IPC

The file manager determines the date of the master configuration file in the index ...\storage\IPC\PLC. If this file

does not exist, the date "01/01/1980 00:00:00" is displayed.

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1080/2 | ECAT Master Config Checksum

Data type: UNSIGNED_32

Index: 23495.2

d

=

0x5BC7.0x02

h

Checksum of the master configuration file in the file system of the IPC

The data manager determines the checksum of the master configuration file in the ...\storage\IPC\PLC directory. If

this file does not exist, the value "0x00000000" is displayed.

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1080/3 | ECAT Stack Master Checksum

Data type: UNSIGNED_32

Index: 23495.3

d

=

0x5BC7.0x03

h

The stack determines the checksum of the loaded/active master configuration file. If there is no loaded/active

master configuration file, the value "0x00000000" is displayed.

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1080/4 | ECAT Bus Scan Match

Data type: UNSIGNED_8

Index: 23495.4

d

=

0x5BC7.0x04

h

Brief information whether the master configuration corresponds to the physical bus structure. The master

configuration of the stack is compared with the actual bus structure.
Selection list

(Lenze setting printed in bold)

Information

0 No match

The master configuration does not correspond to the bus

structure.

1 OK

The master configuration corresponds to the bus

structure.

;

Read access … Write access … CINH … PLC STOP … No transfer