Canopen over ethercat (coe) sdo error codes, 0x98110040 x9811005d, Control technology | ethercat communication manual – Lenze EtherCAT control technology User Manual

Page 161: Diagnostics system error messages

Advertising
background image

DMS 3.1 EN 01/2011 TD17

L

161

Control technology | EtherCAT communication manual

Diagnostics

System error messages

11.7.3

CANOpen over EtherCAT (CoE) SDO error codes (0x98110040 ... 0x9811005D

hex

)

The CoE SDO error codes are relevant for:

 The function blocks ecatSdoUploadReq and ecatSdoDownloadReq.
 SDO read/write error messages caused by SDO requests from the system (e.g.

initialisation code or SDO requests from the engineering tool).

The CoE SDO error codes present the

SDO abort codes

( 164)

.

0x9811002F

EC_E_COE_MBXSND_

WKC_ERROR

SLV

It is not possible to write to the CoE mailbox in the slave. The slave has not yet read the mailbox.

0x98110030

EC_E_COE_MBXRCV_WKC_

Error

SLV

It is not possible to read the CoE mailbox in the slave.

0x98110031

EC_E_NO_MBX_SUPPORT

CTRL

The slave does not support mailbox transfer.

0x98110032

EC_E_NO_COE_SUPPORT

PRJ

Configurator error or the slave description file does not correspond with the slave firmware.

0x98110033

EC_E_NO_EOE_SUPPORT

PRJ

Configurator error or the slave description file does not correspond with the slave firmware.

0x98110034

EC_E_NO_FOE_SUPPORT

PRJ

Configurator error or the slave description file does not correspond with the slave firmware.

0x98110035

EC_E_NO_SOE_SUPPORT

PRJ

Configurator error or the slave description file does not correspond with the slave firmware.

0x98110036

EC_E_NO_VOE_SUPPORT

PRJ

Configurator error or the slave description file does not correspond with the slave firmware.

0x98110037

EC_E_EVAL_VIOLATION

PRJ

The number of slaves indicated in the XML file is too large for the evaluation version of the master.

0x98110038

EC_E_EVAL_EXPIRED

CFG

The evaluation time has expired. The bus is stopped.

Error number [hex]

Designation

Error type Description

Error number [hex]

Designation

Error type Description

0x98110040

EC_E_SDO_ABORTCODE_

TOGGLE

SLV

The status of the toggle bit has not changed.

Abort code 0x05030000

0x98110041

EC_E_SDO_ABORTCODE_

TIMEOUT

SLV

SDO protocol time-out

Abort code 0x05040000

0x98110042

EC_E_SDO_ABORTCODE_

CCS_SCS

SLV

Invalid or unknown specification symbol for the client/server command

Abort code 0x05040001

0x98110043

EC_E_SDO_ABORTCODE_

BLK_SIZE

SLV

Invalid block size (only in "Block mode")

Abort code 0x05040002

0x98110044

EC_E_SDO_ABORTCODE_

SEQNO

SLV

Invalid sequence number (only in "Block mode")

Abort code 0x05040003

0x98110045

EC_E_SDO_ABORTCODE_

CRC

SLV

CRC error (only in "Block mode")

Abort code 0x05040004

0x98110046

EC_E_SDO_ABORTCODE_

MEMORY

SLV

There is not sufficient space in the main memory.

Abort code 0x05040005

0x98110047

EC_E_SDO_ABORTCODE_

ACCESS

SLV

Access to object not supported

Abort code 0x06010000

0x98110048

EC_E_SDO_ABORTCODE_

WRITEONLY

SLV

Read access to a write-protected object

Abort code 0x06010001