Control technology | ethercat communication manual – Lenze EtherCAT control technology User Manual

Page 174

Advertising
background image

Control technology | EtherCAT communication manual

Parameter reference

Interface parameters of the MC-ETC communication card in slot 1

174

L

DMS 3.1 EN 01/2011 TD17

C1096/5

C1096/6

C1096/7

C1096/8

C1096/9

C1096/10

Parameter | Name:

C1096/5 | ECAT Serial Number

Data type: UNSIGNED_32

Index: 23479.5

d

=

0x5BB7.0x05

h

Serial number of the slave

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1096/6 | ECAT Slave Device Name

Data type: VISIBLE_STRING

Index: 23479.6

d

=

0x5BB7.0x06

h

Device name of the slave

The name is stored in the master configuration file.

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1096/7 | ECAT Auto Increment Address

Data type: INTEGER_32

Index: 23479.7

d

=

0x5BB7.0x07

h

The auto-increment address is determined by the slave position. The first node obtains the address "0". Consecutive

descending numbers: 0, -1, -2 ...
Display range

(min. value | unit | max. value)

-65536

0

;

Read access ; Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1096/8 | ECAT Physical Address

Data type: UNSIGNED_16

Index: 23479.8

d

=

0x5BB7.0x08

h

Physical address of the slave

Consecutive ascending numbers, starting with 1001.
Display range

(min. value | unit | max. value)

0

65536

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1096/9 | ECAT Config Physical Address

Data type: UNSIGNED_16

Index: 23479.9

d

=

0x5BB7.0x09

h

The physical slave address set in the master configuration file

This address is assigned by the configurator; consecutive ascending numbers starting with 1001.
Display range

(min. value | unit | max. value)

0

65536

;

Read access … Write access … CINH … PLC STOP … No transfer

Parameter | Name:

C1096/10 | ECAT Alias Address

Data type: UNSIGNED_16

Index: 23479.10

d

=

0x5BB7.0x0A

h

Alias addresses are addresses which are set directly on the device (e.g. via DIP switches).

At the moment, our system does not support alias addresses.
Display range

(min. value | unit | max. value)

0

65536

;

Read access … Write access … CINH … PLC STOP … No transfer