Control technology | EtherCAT communication manual

Commissioning of the system

Detailed commissioning steps

70

L

DMS 3.1 EN 01/2011 TD17

5. Create the control configuration:

• Open the Resources dialog box:

• Open the PLC Configuration dialog box:

6. Add the bus interface to the PLC configuration:

Select the Append subelement BusInterface_EtherCAT command from the

PLC_configuration context menu.

Setting

Description

Automatic calculation of addresses

Every newly added module automatically gets an address which results from

the address of the module integrated before and the size of this module. If a

module is removed from the configuration, the addresses of the subsequent

modules are adapted automatically.

The ExtrasCalculate addresses menu command serves to recalculate the

addresses starting with the currently selected node (module).

Check for overlapping addresses

During the compilation of the project, a check for address overlapping is

carried out and overlapping addresses are indicated.

Save configuration files in project

The data of the configuration file(s) *.cfg and device files on which the

current control configuration is based are stored in the project.

Note!

We recommend to keep the standard setting. In case of a manual address

allocation, you must ensure that each object address is non-ambiguous in the

entire control configuration.
Detailed information on this can be found in the documentation for the »PLC

Designer«.