Control technology | ethercat communication manual, Diagnostics system error messages – Lenze EtherCAT control technology User Manual

Page 158

Advertising
background image

Control technology | EtherCAT communication manual

Diagnostics

System error messages

158

L

DMS 3.1 EN 01/2011 TD17

SLV

Distributed Clocks latching status [...] ([...])

Distributed clocks - latching status

SLV

CoE: SDO Download failure, statVal=[...], errCode=[...] ([...])

CoE: SDO download has failed.

SLV

CoE: SDO Upload failure, statVal=[...], errCode=[...] ([...])

CoE: SDO upload has failed.

SLV

CoE: OD-List Upload failure, statVal=[...], errCode=[...] ([...])

CoE: OD list upload has failed.

SLV

CoE: Object Description Upload failure, statVal=[...], errCode=[...]

([...])

CoE: Object description upload has failed.

SLV

CoE: Object Entry Description Upload failure, statVal=[...],

errCode=[...] ([...])

CoE: Object entry description upload has failed.

SLV

CoE: Emergency transfer failure, statVal=[...], errCode=[...]([...])

CoE: Emergency transfer has failed

SLV

CoE: Emergency request, id=[...], len=[...] ===> slave address=[...],

ErrCode=[...], ErrReg=[...], data: '[...] [...] [...] [...] [...]'.

CoE: Emergency request to slave [...]

SLV

Cyclic command working counter error - Command: [...] -

Logical/Physical address: [...], WKC act/set=[...]/[...]

Cyclic command - WKC error at the node with the logic/physical

address [...]

SLV

Master init command working counter error - Command: [...] -

Logical/Physical address: [...], WKC act/set=[...]/[...]

Master init command - WKC error at the node with the logic/

physical address [...]

SLV

Slave init command working counter error - Properties for slave

\"[...]\": - EtherCAT address=[...] - Command: [...] - Logical/

Physical address: [...], WKC act/set=[...]/[...]

Slave init command - WKC error at the node with the logic/

physical address [...]

SLV

EoE receive working counter error - Properties for slave \"[...]\": -

EtherCAT address=[...] - Command: [...] - Logical/Physical

address: [...], WKC act/set=[...]/%6!lu!

EoE receive - WKC error at the slave with the logic/physical

address [...]

SLV

CoE receive working counter error - Properties for slave \"%1!hs!

- EtherCAT address=%2!lu! - Command: %3!hs! - Logical/

Physical address: 0x%4!lx!, WKC act/set=[...]/[...]

CoE receive - WKC error at the slave with the logic/physical

address [...]

SLV

FoE receive working counter error - Properties for slave \"[...]\": -

EtherCAT address=[...] - Command: [...] - Logical/Physical

address: [...], WKC act/set=[...]/[...]

FoE receive - WKC error at the slave with the logic/physical

address [...]

SLV

SoE receive working counter error - Properties for slave \"[...]\": -

EtherCAT address=[...] - Command: [...] - Logical/Physical

address: [...], WKC act/set=[...]/[...]

SoE receive - WKC error at the slave with the logic/physical

address [...]

SLV

EoE send working counter error - Properties for slave \"[...]\": -

EtherCAT address=[...] - Command: [...] - Logical/Physical

address: [...], WKC act/set=[...]/[...]

EoE send - WKC error at the slave with the logical/physical

address [...]

SLV

CoE send working counter error - Properties for slave \"[...]\": -

EtherCAT address=[...] - Command: [...] - Logical/Physical

address:[...], WKC act/set=[...]/[...]

CoE send - WKC error at the slave with the logical/physical

address [...]

SLV

FoE send working counter error - Properties for slave \"[...]\": -

EtherCAT address=[...] - Command: [...] - Logical/Physical

address: [...], WKC act/set=[...]/[...]

FoE send - WKC error at the slave with the logical/physical

address [...]

SLV

SoE send working counter error – Properties for slave \"[...]\": -

EtherCAT address=[...] – Command: [...] – Logical/Physical

address: [...], WKC act/set=[...]/[...]

SoE send - WKC error at the slave with the logical/physical

address [...]

SLV

Additional error information: [...]

Additional error information [...]

SLV

Ecat command IDX act value=[...]

EtherCAT command - IDX actual value

SLV

Ecat command IDX set value=[...]

EtherCAT command - IDX setpoint

SLV

Init command response error – Properties for slave \"[...]\": -

EtherCAT address=[...] – Current State change of slave=\"[...]\"

No Response, is there a slave at this position?]

Response error to Init command to slave [...]:

No response: Is there a slave at this position?

SLV

Init command response error – Properties for slave \"[...]\": -

EtherCAT address=[...] – Current State change of slave=\"[...]\"

Validation error, is the correct slave at this position?

Response error to Init command to slave [...]:

Validation error: Is the correct slave at this position?

SLV

Init command response error – Properties for slave \"[...]\": -

EtherCAT address=[...] – Current State change of slave=\"[...]\"

target state could not be reached, is the correct slave at this

position?

Response error to Init command to slave [...]:

Target state has not been reached. Is the correct slave at this

position?

SLV

Master init command response error – Current State change of

master=\"[...]\" No Response, is there anything connected?

Response error to master init command:

State change of the master

No response: Is there anything connected at all?

SLV

Master init command response error – Current State change of

master=\"[...]\" Validation error, are the correct slaves

connected?

Response error to master init command:

State change of the master

Validation error, are the correct slaves connected?

SLV

Missing EtherCAT [...] command in Ethernet frame – Properties

for slave \"[...]": - EtherCAT address=[...] – Index of missing

command in the Ethernet frame=[...]

EtherCAT command [...] is missing in the Ethernet frame to slave

[...].

SLV

Mailbox Slave init command timeout – Properties for slave

\"[...]\": - EtherCAT address=[...] – Current State change of

mailbox slave=\"[...]\

Time-out "Mailbox init command" to slave [...]

Error type

Error text in the IPC logbook

Description

Advertising