Fieldbus Status Display Indications B-3

GOOD (Non-Cascade)

Non-Specific

Constant

C

Constant

GOOD (Non-Cascade)

Active Block Alarm

No Limits

A

Alarm-Block

GOOD (Non-Cascade)

Active Block Alarm

Low Limit

A

Alarm-Blck,L

GOOD (Non-Cascade)

Active Block Alarm

High Limit

A

Alarm-Blck,H

GOOD (Non-Cascade)

Active Block Alarm

Constant

A

Alarm-Blck,C

GOOD (Non-Cascade)

Active Advisory Alarm

No Limits

A

Alarm-Advis

GOOD (Non-Cascade)

Active Advisory Alarm

Low Limit

A

Alarm-Advis,L

GOOD (Non-Cascade)

Active Advisory Alarm

High Limit

A

Alarm-Advis,H

GOOD (Non-Cascade)

Active Advisory Alarm

Constant

A

Alarm-Advis,C

GOOD (Non-Cascade)

Active Critical Alarm

No Limits

A

Alarm-Crit

GOOD (Non-Cascade)

Active Critical Alarm

Low Limit

A

Alarm-Crit,L

GOOD (Non-Cascade)

Active Critical Alarm

High Limit

A

Alarm-Crit,H

GOOD (Non-Cascade)

Active Critical Alarm

Constant

A

Alarm-Crit,C

GOOD (Non-Cascade)

Unacknow-ledged Block Alarm

No Limits

A

Alm-U-Block

GOOD (Non-Cascade)

Unacknow-ledged Block Alarm

Low Limit

A

Alm-U-Blck,L

GOOD (Non-Cascade)

Unacknow-ledged Block Alarm

High Limit

A

Alm-U-Blck,H

GOOD (Non-Cascade)

Unacknow-ledged Block Alarm

Constant

A

Alm-U-Blck,C

GOOD (Non-Cascade)

Unacknow-ledged Advisory Alarm

No Limits

A

Alm-U-Advis

GOOD (Non-Cascade)

Unacknow-ledged Advisory Alarm

Low Limit

A

Alm-U-Advs,L

GOOD (Non-Cascade)

Unacknow-ledged Advisory Alarm

High Limit

A

Alm-U-Advs,H

GOOD (Non-Cascade)

Unacknow-ledged Advisory Alarm

Constant

A

Alm-U-Advs,C

GOOD (Non-Cascade)

Unacknow-ledged Critical Alarm

No Limits

A

Alm-U-Crit

GOOD (Non-Cascade)

Unacknow-ledged Critical Alarm

Low Limit

A

Alm-U-Crit,L

GOOD (Non-Cascade)

Unacknow-ledged Critical Alarm

High Limit

A

Alm-U-Crit,H

GOOD (Non-Cascade)

Unacknow-ledged Critical Alarm

Constant

A

Alm-U-Crit,C

GOOD (Cascade)

Non-Specific

No Limits

none

none

GOOD (Cascade)

Non-Specific

Low Limit

L

Low Limit

GOOD (Cascade)

Non-Specific

High Limit

H

High Limit

GOOD (Cascade)

Non-Specific

Constant

C

Constant

GOOD (Cascade)

Acknowledge Initialization (IA)

No Limit

InitAck

GOOD (Cascade)

Acknowledge Initialization (IA)

Low Limit

InitAck,L

GOOD (Cascade)

Acknowledge Initialization (IA)

High Limit

InitAck,H

GOOD (Cascade)

Acknowledge Initialization (IA)

Constant

InitAck,C

GOOD (Cascade)

Request Initialization (IR)

No Limits

R

ReqInit

Table B.1

Fieldbus Status Byte

Suffix

Independent
Status Field

Quality

Substatus

Limits

Advertising