Modes of operation system operation 7-2 – Bio-Rad BioLogic Signal Import Module (SIM) User Manual

Page 131

Advertising
background image

7.1

MANUAL SCREEN

The Manual screen is used to control and monitor the operation of the DuoFlow Workstation and each of its
peripheral devices. This interface is divided into three basic groups of dialogs and includes control panels, a
real time chromatogram display and a status bar.

Figure 7-2. Manual Screen, for the BioLogic DuoFlow system connected to a Maximizer, BioFrac

Fraction collector, QuadTec Detector, Econo Gradient Pump, and Four Valves

From the Manual screen you can control the following:

Gradient Pump: This panel is used to control buffer composition, flow rate and pressure limits (see
Table 2-3) as well as to start and stop the pumps. The Start/Stop buttons are used to start and stop the
pumps. The Set button is used to make changes to the composition, flow rate or pressure limits while the
pumps are running.

BioLogic Duo-Flow - <user name> - <project name> - <method name> - <run name>

Edit

Method

New

Method

New

Run Browser

Manual Setup

Setup

Protocol

wash

load

1

2

Run

Notes

Report

PostRun Log

Advance

Fraction Collector: BioFrac

START

Maximizer+Gradient Pump: F10

pH

1.00

100

0

Inlet B

Flowrate

ml/min

%

%

High

limit

0

1000

Low

limit

psi.

AVR7-3 at port 4

Workstation Valves

SVT3-2 at port 1

SV5-4 at port 2

P

L

2

1

2

1

3

4

STOP

START

STOP

START

STOP

Set

Set

psi.

Econo Gradient Pump 1

EGP %B

1.000

0

0.00

% Split

Flow
Direction

Flowrate

ml/min

%

%

Set

Tube #:

Rack Pos:
Tube #:

A

Tube #: Grid #:

ml

Vol. left:

Mode:

System

Local

Mode:

System

Local

Mode:

System

Local

Start:

Rack:

End:

Fraction size:

1

1F

1A

1

Lamp Type

Range

Deuterium

190 - 370 nm

90

1.00

nm

280

A

B

I

AVR9-8 at port 5

3

7

8

2

6

5

4

I

QuadTec Detector

ON

OFF

Zero Baseline

Wavelength Selection

2.00

100% Buffer B

0

2

4

6

8

10

Min. Tenth

AU

mS/cm

1.50

1.00

0.50

50

0.00

500.0

0.0

400.0

300.0

200.0

100.0

Fractions

UV

Conductivity

Clear

Traces

Resize

WL1 - 280nm

0.0041 AU

WL2 - 260nm

-0.00001 AU

WL3 - 214nm

0.00021 AU

WL4 - 405nm

0.00004 AU

Flow Rate

EGP %B

0 %B

0.00 ml/min

0%

% Split

1.00ml/min

0 %B2

Maximizer + Gradient Pump: F10

UV

Conductivity

438 psi

1.003 AU

1.23 mS/cm

QuadTec

Econo Gradient

Pump

SIM1/pH

SIM1/SIG

0.548 Volt

7.00 pH

Settings

nm

260

nm

214

nm

405

CONTENTS
MAY VARY
DEPENDING ON
CONFIGURATION

File View

Utilities

Options

Window

Help

Bio-Rad

Web

Rack: F1 (12-13 mm tubes)

Setup

Mode:

System

Local

B

MODES OF OPERATION

SYSTEM OPERATION

7-2