Modes of operation system operation 7-39 – Bio-Rad BioLogic Signal Import Module (SIM) User Manual

Page 168

Advertising
background image

Figure 7-11b. Post-Run Screen showing a Time-based Chromatogram

and "Rack and Grid#" fraction numbering

7.5.1

Resizing

The main chromatogram shows the current “Zoom” region. To resize the image (or “zoom in” to a particular
region of the chromatogram), either change the axes scale in the reference chromatogram, or use the
“rubber band” controls on either chromatogram. To use the rubber band controls, click and hold the left
mouse button. Drag it across the chromatogram region. Release the mouse button and the main
chromatogram will be resized. Click on the Full View button in the toolbar to return to normal view.

7.5.2

Chromatogram Information (Values at Cursor)

The top left corner of the PostRun screen contains information about the chromatogram. The Values at
Cursor window in the upper left corner will list up to eight detector traces depending on the devices selected
in the runs device setup. The position of the vertical bar within the main chromatogram dictates the displayed
information. Run time, absorbance (AU), conductivity (mS/cm), gradient progression (%B), and the activity
trace values are displayed for each trace at the position of the vertical bar. To view the vertical bar, place the
cursor inside the main chromatogram.

Tags

AU

SA

FullView Print

Del Tag

Activity

Edit

View

Utilities

Options

Edit

Method

New

Method

New

Run

Manual

Setup

Values at Cursor

Current Tagging Trace:

QuadTec-3 (214 nm)

Run Time:

Gradient:

QuadTec-1 (280 nm):
QuadTec-2 (260 nm):
QuadTec-3 (214 nm):
QuadTec-4 (405 nm):

Conductivity:

GP pressure:

No Trace:

00:03:38.4
21% Buffer B
0.0345 AU
0.0228 AU
0.4762 AU
0.0021 AU
8.47 mS/cm
375.53 psi

Protocol

wash

load

1

2

Run

Notes

Report

PostRun

Settings

Log

Help

File

Browser

QuadTec-3 (214 nm)

GP pressure

BioLogic

Duo-Flow

- <user name> - <project name> - <method name> - <run name>

WL1 - 280nm

0.40

WL2 - 260nm

0.15

WL3 - 214nm

2.00

WL4 - 405nm

0.00

Flow Rate

EGP %B

0 %B

0.00 ml/min

0%

Split

1.00ml/min

0 %B

Gradient Pump: F-40

UV

Conductivity

438 psi

0.03775 AU

359 mS/cm

QuadTec

Econo Gradient

Pump

SIM1/pH

SIM1/SIG

0.953 Volt

0.00 pH

50

100% Buffer B

AU

50.0

0.0

-10.0

40.0

30.0

20.0

10.0

Fractions

A

mS/cm

B

0.00

1F

1

A

2F

3F

4F

5F

6F

7F

8F

9F

10F

11F

12F

13F14F

4.00

2.00

6.00

2

3

4

0.100

0.075

0.050

0.025

-0.000

Min. Tenth

Rack Pos:
Grid #:

MODES OF OPERATION

SYSTEM OPERATION

7-39