S-0-0002 communication cycle time (tscyc), S‐0‐0002 – BECKHOFF AX5000 S-IDN Parameters User Manual

Page 10

Advertising
background image

S­IDNs

S­0­0002 Communication cycle time (tScyc)

The parameter contains information regarding the time intervals at which the fieldbus (EtherCAT) transfers
the cyclic data of the master data telegram (MDT) and the drive telegram (AT).

Attributes

Name

Value

Format

UDEC

Data length

16

Decimal point

0

Min value

125

Max value

20 000

Default value

500

Unit

µs

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

Yes

Related to interface revision

No

This parameter must be transferred in PreOp from the master to the slave and is active in the slave from
SafeOp. This parameter is defined as 125 μs, 250 μs etc. up to 20000 μs, in increments of 250 μs. Values
permitted in S­0­0002 depend on the position controller cycle.

AX5000 ­ IDN­Descriptions

10

Version 3.1

Advertising