S­IDNs

S­0­0124 Standstill window

The parameter contains a velocity threshold value, which is used to detect a motor or axis standstill.

Attributes

Name

Value

Format

udec

Data length

32

Decimal point

0

Min value

0

Max value

17895697

Default value

89478

Unit

rev/(2

30 

ms)

Changeable in EtherCAT state

PreOp, SafeOp, Op

Cyclic transfer

No

Device parameter

No

Related to interface revision

If the magnitude of actual velocity falls below the value of this parameter, the axis velocity is in the so­called
standstill window. This results in bit 1 of S­0­0013 being set. In addition, this window is evaluated in the
AxisStateMachine. Further actions are executed, depending on this threshold value. For example, in motors
with holding brake, the brake is engaged depending on this window. Default (89478) equates to 5 rpm.

Note

IDNs involved

S‐0‐0207 [

}

 139], S‐0‐0013 [

}

 16], S‐0‐0040 [

}

 45]

Note

Additional functional description

See also AxisStateMachine documentation (to do!).