S­IDNs

S­0­0040 Velocity feedback value 1

The parameter contains the actual velocity value. It is determined from the signals of feedback system 1. If
the observer is active, the signal is transmitted by the observer.

Attributes

Name

Value

Format

dec

Data length

32

Decimal point

0

Min value

­2 147 483 648

Max value

2 147 483 647

Default value

­

Unit

Rev / (2

30

 ms)

Changeable in EtherCAT state

No

Cyclic transfer

AT

Device parameter

No

Related to interface revision

No

Scaling see S­0­0036.

Note

IDNs involved

S‐0‐0036 [

}

 43]S‐0‐0044 [

}

 47], S‐0‐0045 [

}

 48], S‐0‐0046 [

}

 49]