S­IDNs

S­x­0111 Motor continuous stall current

The parameter contains the RMS value of the motor standstill current. It is permissible to energize the motor
continuously with the standstill current, which generates the standstill torque. This parameter can be used as
a reference for all motors except asynchronous motors, to determine torque values / forces and motor­
dependent currents.

Attributes

Name

Value

Format

udec

Data length

32

Decimal point

3

Min value

­

Max value

­

Default value

­

Unit

A

Changeable in EtherCAT state

PreOp

Cyclic transfer

No

Device parameter

No

Related to interface revision

No

Note

Parameter set switchover is possible!

This IDN exists as S­0­0111; S­1­0111; S­2­0111; S­3­0111; S­4­0111; S­5­0111; S­6­0111
and S­7­0111. Ex factory, all values are identical.

AX5000 ­ IDN­Descriptions